loading

PROVIDE CUSTOM EDITING

YOSION Machinery Committed to stable performance automatic pet bottle blowing machine production line since 1990s

Safety production specification for automatic blow molding machine

by:Yosion Machinery     2022-05-12
Specifications for safe operation of automatic blow molding machine In our daily production, we must implement the importance of safe production in every link, so that every employee can understand the safety points and correct operation methods, and prevent work-related injuries and major equipment. In the event of an accident, safety management can be carried out from the following aspects: 1. Dressing: 1. Girls should tie their braids behind their heads and cover them with hats, and it is forbidden to have hair loose. 2. Do not wear jewelry such as rings, bracelets, earrings, etc. 3. Wear flat shoes and non-slip work shoes. 4. Boys are not allowed to wear shorts and vests, and girls are not allowed to wear skirts, uniformly wear work clothes and tie the cuffs. Code of conduct: 1. Do not tap, slap and its buttons too hard; 2. Transfer, use tools, handle with care 3. Prohibit drinking and over-fatigue operation. Lubricate each moving part once. (manipulator, manipulator guide rail, mold opening and closing guide rail). 2. The swing arm can be added once every (3-4) days. The large chain and small chain of the heating machine can be used once a month. Regularly check whether the main engine reducer is short of oil. , 3. Before production, check whether the moving parts are firm, whether the screws are loose and falling off, whether the buffer is damaged and ensure normal work, and whether the belt transmission part is abnormal. 4. Check whether the high-pressure air source, low-pressure air source, power supply, and water source are normal. 5. Check whether each emergency stop switch, safety door switch, and detection switch of the protection device are normal. 6. It is forbidden to overdo it too quickly when pouring embryos in the hopper. 7. Check whether the heating head feeds the embryo and whether the degermination part works normally. 8. Check whether the lamp tube is damaged or broken. To be replaced in time. 9. Check whether each pneumatic component is leaking and whether the action is sensitive. 10. The blowing mold must be cleaned regularly. 11 When opening the high and low pressure air source switch, it must be moved slowly to prevent the air source from blowing too fast and dirt is blown into the solenoid valve. At the same time, open the exhaust valve for 30 seconds to ensure that the air is clean. 12. When starting the machine, make sure that the mechanical parts are in good condition, there is no one inside the machine, and there is no foreign matter. Also close the safety door. 13. When starting the machine, the main drive motor must be started first, and the heating machine must be started with a delay of 30 seconds to prevent voltage fluctuations. Before starting the heating, make sure that the cooling water is turned on to prevent the cooling plate from being deformed due to excessive heating. 14. Start heating and wait until the oven temperature evenly rises to the preset temperature, then press the embryo button, and the blowing bottle will be opened at the same time. 15. When the machine is running, it is necessary to pay close attention to whether the machine has abnormal noise. It is necessary to detect it early and stop it in time to solve it. 16. In case of emergency, press the emergency stop button to brake in an emergency. Then analyze the cause of the formation according to the on-site situation, and find the problem and solve it quickly. 17. It is forbidden to stop or stop the equipment at will when there is no fault. 18. Non-professionals are prohibited from opening or checking and repairing the electrical cabinet. 19. After the machine is running normally, do not put any part of the body into the machine to avoid injury by the manipulator. If the machine has abnormal noise, it can be stopped and then transferred to the jog mode for observation. 20. When the machine is being repaired, take a photo of the emergency stop button, turn off the power of the equipment and post a maintenance sign to ensure safe maintenance, and the main power can be turned off if necessary. 21. For non-workers, it is forbidden to approach the console. Please stay away from the equipment to avoid injury.
Yosion Machinery thinks that customer satisfaction is one of the most important determinants of brand loyalty. High-quality service can be the difference between a one-time buyer and a lifelong repeat customer.
If you are interested in any of bottle blowing machine, please feel free to contact us.
If our brand is successful and consistent, it will be much easier to initially grab customers and encourage them to purchase bottle blowing machine further.
Making a few technical tweaks to the way you structure and distribute bottle blowing machine could be the difference between an engaging, thought-provoking product and a perfunctory one.
Custom message
Chat Online
Chat Online
Leave Your Message inputting...