Bottle blowing machine maintenance five items
by:Yosion Machinery
2020-06-12
Bottle blowing machine feeding a not charging: need to check several ways: whether there had been no material hopper, if is: need to charging not: please check whether the elevator control contactor in electrical state, if it is to state, to check whether the motor is in power and load state, because this kind of situation is likely to be the bottle preform ( Embryo) Stuck with ascension, then the simplest method is to promote human help. If you examine elevator control contactor is not to state, please check whether the bottle embryo detect magic eye with reflector plate is not on the same line.